X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 18% PEG3350, 10% N,N-Dimethyldodecylamine N-oxide (LDAO), 0.2 M sodium sulphate
Unit Cell:
a: 55.482 Å b: 103.711 Å c: 163.199 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 3.32 Solvent Content: 62.95
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 3.1000 48.9210 17687 893 99.6600 0.2250 0.2585 64.6274
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.100 48.921 99.900 0.279 ? 6.500 6.600 ? 17774 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.100 3.310 99.900 ? ? ? 6.600 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.953732 Australian Synchrotron MX2
Software
Software Name Purpose Version
Aimless data scaling 0.7.4
PHENIX refinement 1.15_3459
PDB_EXTRACT data extraction 3.27
XDS data reduction .
PHASER phasing .