7MSQ

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.9 293 Protein complex (5 mg/mL in 25 mM Tris (pH 8.0), 200 mM NaCl) was mixed with an equal volume (2 uL) of well solution comprising 100 mM BisTrisPropane (pH 6.9), 800 mM KSCN, 10% (v/v) glycerol, and 18%(m/v) PEG8000
Unit Cell:
a: 109.764 Å b: 115.494 Å c: 240.758 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.65 Solvent Content: 53.51
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.2900 48.0000 65175 3368 99.7800 0.1966 0.2447 50.2590
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.290 48.150 99.800 0.075 ? 22.500 13.700 ? 68595 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.290 2.350 97.500 ? ? ? 13.400 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
REFMAC refinement 5.8.0267
XDS data reduction .
Aimless data scaling 0.7.4
PHASER phasing 2.8.3
PDB_EXTRACT data extraction 3.27