X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6 295 15% PEG 2000 MME, 100 mM MES
Unit Cell:
a: 98.629 Å b: 98.629 Å c: 82.020 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 61
Crystal Properties:
Matthew's Coefficient: 2.11 Solvent Content: 41.60
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION FOURIER SYNTHESIS THROUGHOUT 1.4600 26.9000 77574 5992 98.9900 0.1814 0.2081 22.7045
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.46 30.000 99.100 0.062 ? 13.200 3.300 ? 77575 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.500 1.530 98.200 ? ? ? 3.100 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 22-BM 1 APS 22-BM
Software
Software Name Purpose Version
HKL-2000 data scaling .
PHENIX refinement 1.18.2_3874
PDB_EXTRACT data extraction 3.27
HKL-2000 data reduction .
PHENIX phasing .