7M2O

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 298 0.1 M Tris-HCL pH 8.5, 25 % (w/v) PEG 1000
Unit Cell:
a: 96.904 Å b: 96.904 Å c: 79.536 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: I 4
Crystal Properties:
Matthew's Coefficient: 2.19 Solvent Content: 43.82
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.07 39.77 21419 1065 99.81 0.12793 0.16607 21.264
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.07 50.00 99.9 0.095 ? 14.6 6.0 ? 22486 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.07 2.11 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 1.54 ? ?
Software
Software Name Purpose Version
REFMAC refinement 5.8.0257
HKL-3000 data reduction .
HKL-3000 data scaling .
MOLREP phasing .