ELECTRON MICROSCOPY


Sample

BG505 SOSIP reconstructed from a designed nanoparticle, BG505 SOSIP-T33-31 (Component B)

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument FEI VITROBOT MARK IV
Cryogen Name ETHANE
Sample Vitrification Details Blotting time varied between 3 and 7 seconds.
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 64726
Reported Resolution (Å) 3.8
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol RIGID BODY FIT
Refinement Target ?
Overall B Value ?
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å2) 50.0
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model FEI TALOS ARCTICA
Minimum Defocus (nm) 800
Maximum Defocus (nm) 2000
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model OTHER
Nominal Magnification 36000
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 200
Imaging Details ?
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION RELION 3.0
IMAGE ACQUISITION Leginon ?
CTF CORRECTION RELION 3.0
MODEL FITTING UCSF Chimera ?
MODEL REFINEMENT Coot ?
MODEL REFINEMENT RosettaEM ?
INITIAL EULER ASSIGNMENT RELION 3.0
FINAL EULER ASSIGNMENT RELION 3.0
CLASSIFICATION RELION 3.0
RECONSTRUCTION RELION 3.0
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION ?