Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Documentation
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
7KFR
pdb_00007kfr
10.2210/pdb7kfr/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
Adeno-associated virus
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
Two 3uL aliquots applied to grid (manual blotting between), prior to automated 3 second blot before plunging.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
48209
Reported Resolution (Å)
1.56
Resolution Method
FSC 0.143 CUT-OFF
Other Details
These 48209 particles refined to approx. 2.2 A with I1 symmetry, and subsequent refinements of beam tilt and per-particle CTF brought the resolution to 1.8 A. Further particle-polishing and subsequent re-refinement of CTF brought the resolution to 1.70 A and a final reconstruction using Ewald sphere correction ended at 1.56 A. The map used for modeling was sharpened using the volume whitening routine in cisTEM.
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
Least-squares residual
Overall B Value
?
Fitting Procedure
?
Details
Stand-alone RSRef was used for refinement of magnification, resolution, envelope correction and atomic B-factors. This was alternated with RSRef-embedded CNS was used for molecular dynamics optimization (1st round) and stereochemically-restrained all-atom least-squares optimization.
Data Acquisition
Detector Type
FEI FALCON III (4k x 4k)
Electron Dose (electrons/Å
2
)
30
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
-800
Maximum Defocus (nm)
-2600
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
155000
Calibrated Magnification
154400
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Coma-free alignment and objective astigmatism where corrected using Sherpa (Thermo Fisher, Inc.).
Imaging Experiment
Task
Software Package
Version
PARTICLE SELECTION
DoG Picker
?
IMAGE ACQUISITION
EPU
?
CTF CORRECTION
Gctf
?
MODEL FITTING
Coot
0.8.9.2
INITIAL EULER ASSIGNMENT
RELION
3.0
FINAL EULER ASSIGNMENT
RELION
3.0
CLASSIFICATION
RELION
3.0
RECONSTRUCTION
RELION
3.0
MODEL REFINEMENT
RSRef
0.5.8
MODEL REFINEMENT
CNS
1.3
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING ONLY
?
Feedback
Feedback Form
Name
Email
Institute
Feedback
Submit