Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
7JPN
pdb_00007jpn
10.2210/pdb7jpn/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
bovine Arp2/3 complex with Arpin
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
LEICA EM CPC
Cryogen Name
ETHANE
Sample Vitrification Details
Grids were manually blotted for 3 seconds with Whatman 41 filter paper and manually plunged using a Leica EM CPC manual plunger.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
182324
Reported Resolution (Å)
3.24
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
correlation
Overall B Value
132
Fitting Procedure
?
Details
?
Data Acquisition
Detector Type
GATAN K3 (6k x 4k)
Electron Dose (electrons/Å
2
)
50
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
-1500
Maximum Defocus (nm)
-3500
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
165000
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Data were collected in super-resolution mode with an illuminated area of 1.01 um, nominal dose of 40 e-/A^2, a dose rate of 4.87 e-/s/pixel, and 2 or 5 exposures per hole by image shift.
Imaging Experiment
Task
Software Package
Version
IMAGE ACQUISITION
Latitude
?
CTF CORRECTION
CTFFIND
4.1.13
CTF CORRECTION
cryoSPARC
2.12.4
MODEL FITTING
Coot
?
INITIAL EULER ASSIGNMENT
cryoSPARC
2.12.4
FINAL EULER ASSIGNMENT
cryoSPARC
2.12.4
CLASSIFICATION
cryoSPARC
2.12.4
RECONSTRUCTION
cryoSPARC
2.12.4
MODEL REFINEMENT
PHENIX
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
CTF correction was done in cryoSPARC for intial 2D classification and then repeated in CTFFIND4 (Relion) for classification and final reconstruction.