X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.0 293 25% PEG 1500, 0.1 M MMT, pH 9.0, soaked with 10 mM GTP 1 hr, back soaked 22h with no GTP
Unit Cell:
a: 40.166 Å b: 79.515 Å c: 90.892 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: ? Solvent Content: ?
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.15 20.0 16120 804 97.85 ? 0.2439 55.00
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.15 20.0 98.1 0.077 ? 22.3 6.7 ? 16163 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.15 2.19 ? ? ? 1.3 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSRRC BEAMLINE TPS 05A 1.0 NSRRC TPS 05A
Software
Software Name Purpose Version
PHENIX refinement v1.17.1
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .