X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 0.2M Magnesium Formate, 23-30% (v/v) Polyethylene glycol 3350
Unit Cell:
a: 46.038 Å b: 64.223 Å c: 91.554 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 2 21
Crystal Properties:
Matthew's Coefficient: 2.74 Solvent Content: 55.14
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.9990 41.1310 18639 1863 98.1000 0.1888 0.2173 26.9012
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.990 50.000 99.400 0.156 ? 4.500 12.900 ? 18929 ? ? 23.640
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.000 2.030 98.200 ? ? ? 12.300 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 195 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL19U1 1 SSRF BL19U1
Software
Software Name Purpose Version
HKL-2000 data reduction .
SCALEPACK data scaling .
PHASER phasing 2.6.0
PHENIX refinement 1.10.1_2155
PDB_EXTRACT data extraction 3.27