X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.0 289 0.1M MES (pH 6.0), 3% DMSO, 10% PEG 6000
Unit Cell:
a: 55.802 Å b: 99.122 Å c: 59.752 Å α: 90.000° β: 108.990° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.31 Solvent Content: 46.75
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.0040 28.5220 37990 1988 92.1000 0.1781 0.2169 26.8510
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2 50 92.50 0.047 ? 34.28 6.5 ? 38120 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.0 2.03 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL19U1 0.97852 SSRF BL19U1
Software
Software Name Purpose Version
SCALA data scaling .
PHENIX refinement 1.14_3228
PDB_EXTRACT data extraction 3.27
HKL-3000 data reduction .
PHASER phasing .