Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
7CFT
pdb_00007cft
10.2210/pdb7cft/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
hASIC1a-Mamba1
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
Purified hASIC1a-Mamba1 complex (3 ul) at a concentration of 3.1 mg/ml was added to the freshly plasma-cleaned holey carbon grid (Quantifol, R1.2/1.3, 300 mesh, Cu), blotted for 5 s at 100% humidity with a Vitrobot Mark IV (ThermoFisher Scientific) and plunge frozen into liquid ethane cooled by liquid nitrogen.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
119901
Reported Resolution (Å)
3.9
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
?
Refinement Protocol
FLEXIBLE FIT
Refinement Target
?
Overall B Value
?
Fitting Procedure
?
Details
?
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å
2
)
50
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
?
Maximum Defocus (nm)
?
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
?
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
?
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Grids were transferred to a Titan Krios electron microscope (FEI) operated at 300 kV equipped with a Gatan K2 Summit direct detection camera. Images of hASIC1a-Mamba1 complex was collected using the automated image acquisition software SerialEM in counting mode with 29,000x magnification yielding a pixel size of 1.014 A. The total dose of 50 e-/A2 was fractionated to 40 frames with 0.2 s per frame. Nominal defocus values ranged from -1.8 to -2.5 um. The dataset of hASIC1a included 3,364 micrographs.
Imaging Experiment
Task
Software Package
Version
PARTICLE SELECTION
RELION
2.1
CTF CORRECTION
Gctf
?
MODEL FITTING
UCSF Chimera
?
MODEL REFINEMENT
PHENIX
?
CLASSIFICATION
RELION
2.1
RECONSTRUCTION
RELION
2.1
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
?