X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 285 20% polyethylene glycol 3350, 0.2M Potassium fluoride
Unit Cell:
a: 61.618 Å b: 105.512 Å c: 125.487 Å α: 90.000° β: 94.960° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.02 Solvent Content: 39.14
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.5000 28.5600 228063 12012 94.0600 0.1406 0.1650 13.4410
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.500 50.000 94.300 0.084 ? 11.200 6.100 ? 240435 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.500 1.530 92.400 ? ? ? 6.000 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PAL/PLS BEAMLINE 7A (6B, 6C1) 0.97934 PAL/PLS 7A (6B, 6C1)
Software
Software Name Purpose Version
HKL-2000 data scaling .
REFMAC refinement 5.8.0238
PDB_EXTRACT data extraction 3.25
HKL-2000 data reduction .
MOLREP phasing .