7BFL

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 293 25% w/v PEG 3350, 0.2 M sodium chloride and 0.1 M Bis-Tris pH 6.5
Unit Cell:
a: 110.070 Å b: 93.070 Å c: 66.780 Å α: 90.000° β: 117.190° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.83 Solvent Content: 56.55
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.8800 67.4600 12745 705 98.9200 0.2613 0.3076 49.4620
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.88 70.00 96.2 ? ? 3.4 3.4 ? 13043 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.88 3.06 ? ? ? 1.2 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 HF 1.5418 ? ?
Software
Software Name Purpose Version
REFMAC refinement 5.8.0267
PDB_EXTRACT data extraction 3.27
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .