7BFK

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.4 293 32% w/v PEG 4000, 0.2 M sodium acetate trihydrate, 0.1 M Tris-HCl pH 7.4 and 1% v/v acetonitrile
Unit Cell:
a: 28.968 Å b: 70.747 Å c: 53.545 Å α: 90.000° β: 90.930° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 1.97 Solvent Content: 37.56
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.8900 26.8200 16429 902 99.2500 0.1859 0.2188 41.1360
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.89 50.0 99.4 0.072 ? 15.2 3.0 ? 17350 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.89 1.96 96.3 ? ? 2.4 1.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 HF 1.5418 ? ?
Software
Software Name Purpose Version
REFMAC refinement 5.8.0267
PDB_EXTRACT data extraction 3.27
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .