X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 Crystals were obtained from hanging drops by mixing a 1:1 ratio of protein solution with well solution containing 2 M AmSO4, 0.1 M NaCl and 0.1 M Bis-tris pH 6.1-6.2
Unit Cell:
a: 57.950 Å b: 72.080 Å c: 158.160 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.26 Solvent Content: 45.55
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.7000 24.7600 74282 3664 99.9000 0.1940 0.2140 40.1700
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.7 79.1 99.4 0.039 ? 20.9 6.4 ? 473128 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.7 1.74 93 ? ? 1.8 4.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON MAX IV BEAMLINE BioMAX 0.976 MAX IV BioMAX
Software
Software Name Purpose Version
BUSTER refinement 2.11.7
PDB_EXTRACT data extraction 3.27
XDS data reduction .
STARANISO data scaling .
PHASER phasing .