X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.0 277.15 20 mM sodium acetate 50 mM NaCl 5 mM D-fructose 10 mM sclx8
Unit Cell:
a: 59.478 Å b: 59.478 Å c: 64.720 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 3
Crystal Properties:
Matthew's Coefficient: 3.36 Solvent Content: 59
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.2610 40.3030 68299 3490 98.8700 0.1454 0.1619 19.6227
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.26 64.72 99.0 ? ? 16.4 1.0 ? 68362 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.26 1.28 97.1 ? ? ? 2.9 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 2 0.98 SOLEIL PROXIMA 2
Software
Software Name Purpose Version
PHENIX refinement 1.10.1_2155
PDB_EXTRACT data extraction 3.25
XDS data reduction .
Aimless data scaling .
PHASER phasing .