X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 293 pBAF was crystallized by the hanging drop method against 0.2 M sodium fluoride, 20% w/v PEG 3350
Unit Cell:
a: 70.320 Å b: 70.320 Å c: 40.625 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 2.95 Solvent Content: 58
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 3.0040 35.1600 1799 171 73.2000 0.2076 0.3261 68.6800
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.00 36 100 ? ? 7.8 19.4 ? 2463 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.00 3.18 100 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PETRA III, EMBL c/o DESY BEAMLINE P14 (MX2) 1.0332 PETRA III, EMBL c/o DESY P14 (MX2)
Software
Software Name Purpose Version
BUSTER refinement 2.10.3 (19-MAR-2020)
PDB_EXTRACT data extraction 3.25
XDS data reduction .
STARANISO data scaling .
PHENIX phasing .
Feedback Form
Name
Email
Institute
Feedback