X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.25 293 Well solution: 0.1 M Na-Citrate pH 4.25 / 17.5% PEG 6K The crystals were cryo-protected by dipping them in mother liquor with increased 25% PEG 6K
Unit Cell:
a: 45.230 Å b: 89.806 Å c: 67.005 Å α: 90.000° β: 103.960° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.34 Solvent Content: 47.50
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.8500 39.0000 40691 2110 96.4500 0.1887 0.2239 33.3080
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.85 39.44 96.5 0.084 ? 11.7 6.5 ? 42829 ? 1.2 19.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.85 1.89 75.4 ? ? 1.2 4.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON MAX IV BEAMLINE BioMAX 0.82656 MAX IV BioMAX
Software
Software Name Purpose Version
REFMAC refinement 5.8.0103
PDB_EXTRACT data extraction 3.25
XDS data reduction .
Aimless data scaling .
MOLREP phasing .