X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 277 0.095 M HEPES, pH 7.1, 29% PEG 400, 0.19 M CaCl2, 5% glycerol
Unit Cell:
a: 82.260 Å b: 111.730 Å c: 62.510 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.59 Solvent Content: 52.53
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.2500 55.8650 79638 1990 99.9200 0.1415 0.1597 17.6523
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.250 66.240 99.900 0.101 ? 12.400 11.700 ? 79674 ? ? 12.320
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.250 1.270 98.800 ? ? ? 7.600 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PETRA III, DESY BEAMLINE P11 1.0332 PETRA III, DESY P11
Software
Software Name Purpose Version
MOSFLM data reduction .
Aimless data scaling 0.6.3
PHASER phasing 2.8.1
PHENIX refinement .
PDB_EXTRACT data extraction 3.24