X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8 294 MiaE: 20 mg/ml in 100 mM HEPES, pH 7.5, 30mM NaCl reservoir solution: 0.5M CaCl2, 42% PEG 6k, 2M Tris-Cl pH 8
Unit Cell:
a: 116.797 Å b: 50.929 Å c: 76.258 Å α: 90.000° β: 91.000° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.51 Solvent Content: 50.93
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.7000 46.7520 48185 2501 97.3000 0.1897 0.2166 36.9550
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.7 50 97.5 ? ? 13.1 2.8 ? 48290 ? 1.44 38.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.7 1.8 97.7 ? ? ? 2.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.9753 ESRF ID29
Software
Software Name Purpose Version
PHENIX refinement 1.1
PDB_EXTRACT data extraction 3.25
XDS data reduction .
XSCALE data scaling .
PHASER phasing .