Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
6Z7P
pdb_00006z7p
10.2210/pdb6z7p/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
S-layer
Specimen Preperation
Sample Aggregation State
CELL
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
NITROGEN
Sample Vitrification Details
1.5 s blot
3D Reconstruction
Reconstruction Method
SUBTOMOGRAM AVERAGING
Number of Particles
51866
Reported Resolution (Å)
4.8
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Tomogram generation in IMOD using the NovaCTF implementation of Turonova and Briggs. Sub-tomogram averaging performed using the AV3 package (Friedrich Foerster) applied to tubular specimens (Bharat et al, PLoS Biology, 2011)
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
RIGID BODY FIT
Refinement Target
USCF Chimera
Overall B Value
?
Fitting Procedure
?
Details
Initial rigid body fit of the C-terminal X-ray structure (PDB: 5N8P, amino acids 249-1046) and the N-terminal cryo-EM structure (PDB: 6T72, amino acids 2-243) was performed in USCF Chimera. The missing amino acid linker was manually added suing Coot. The model was not refined against the map and all B-factors were set to zero due to resolution anisotropy.
Data Acquisition
Detector Type
GATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å
2
)
3.4
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
-2000
Maximum Defocus (nm)
-5000
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
105000
Calibrated Magnification
105000
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
VOLUME SELECTION
RELION
1.4
IMAGE ACQUISITION
SerialEM
?
MODEL FITTING
UCSF Chimera
1.13
MODEL FITTING
Coot
0.9-pre
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
Following Turonova and Briggs NovaCTF