6Z7E

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 277 19-24 % PEG 400 100 mM TEA/HCl pH=7.5 10 % (v/v) isopropanol
Unit Cell:
a: 46.936 Å b: 71.033 Å c: 130.614 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.08 Solvent Content: 40.80
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.663 39.16 52131 4941 99.79 0.1857 0.2083 39.0156
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.663 39.16 99.79 ? ? 19.44 13.2 ? 52136 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.663 1.723 ? ? ? 1.9 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SLS BEAMLINE X06DA 1 SLS X06DA
Software
Software Name Purpose Version
SCALA data scaling .
PHENIX refinement 1.17.1_3660
PDB_EXTRACT data extraction 3.25
Coot model building .