Planned Maintenance: Some services may turn out to be unavailable from 15th January, 2026 to 16th January, 2026. We apologize for the inconvenience!

X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 298 200 mM CaCl2, 100 mM imidazole, pH 8.0, 14% PEG 8,000
Unit Cell:
a: 61.934 Å b: 61.934 Å c: 171.509 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 2.20 Solvent Content: 44.07
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.4000 24.9300 13568 1357 98.5000 0.2172 0.2758 64.4257
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.400 25.000 98.200 0.077 ? 9.000 4.700 ? 13591 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.400 2.490 92.900 ? ? ? 4.200 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-C 0.97920 APS 24-ID-C
Software
Software Name Purpose Version
HKL-2000 data scaling .
PHENIX refinement 1.17.1_3660
PDB_EXTRACT data extraction 3.25
HKL-2000 data reduction .
PHENIX phasing .
Feedback Form
Name
Email
Institute