Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
6XMX
pdb_00006xmx
10.2210/pdb6xmx/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
B-cell lymphoma 6 protein (BCL6) filament
Specimen Preperation
Sample Aggregation State
FILAMENT
Vitrification Instrument
LEICA EM GP
Cryogen Name
ETHANE
Sample Vitrification Details
4 ul sample applied twice, blotted 1.3s each time
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
112048
Reported Resolution (Å)
3.7
Resolution Method
FSC 0.143 CUT-OFF
Other Details
as implemented in Relion
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
RIGID BODY FIT
Refinement Target
?
Overall B Value
?
Fitting Procedure
?
Details
Real_space_refine: global minimization, rigid body and adp refinement with target restraints.
Data Acquisition
Detector Type
GATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å
2
)
63.4
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
-1000
Maximum Defocus (nm)
-2500
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
105000
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Data collection in counting mode, using multi shot scheme (4 holes per stage position, 2 shots per hole)
Imaging Experiment
Task
Software Package
Version
PARTICLE SELECTION
crYOLO
?
IMAGE ACQUISITION
SerialEM
?
CTF CORRECTION
CTFFIND
?
CTF CORRECTION
RELION
?
MODEL FITTING
Coot
0.89
MODEL REFINEMENT
PHENIX
1.17
INITIAL EULER ASSIGNMENT
RELION
3.0
FINAL EULER ASSIGNMENT
RELION
3.0
CLASSIFICATION
RELION
3.0
RECONSTRUCTION
RELION
3.0
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
Standard CTF correction in relion, based on parameters estimated by CTFFIND4