X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 291 PEG 10000, Li2SO4, pH 7.0
Unit Cell:
a: 108.280 Å b: 108.280 Å c: 42.202 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 61
Crystal Properties:
Matthew's Coefficient: 2.11 Solvent Content: 41.74
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.6000 33.2840 37117 1912 98.7800 0.1589 0.1804 26.5849
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.600 35.000 98.800 0.085 ? 7.700 7.600 ? 37127 ? ? 17.620
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.600 1.630 93.900 ? ? ? 6.000 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 93 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-F 0.97872 APS 21-ID-F
Software
Software Name Purpose Version
SCALEPACK data scaling .
PHENIX refinement 1.16-3549-000
PDB_EXTRACT data extraction 3.25
HKL-2000 data reduction .
PHASER phasing .