X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6 293 35 mg/ml peptide in LCP 25% w/v poly(ethylene glycol) 1500 10% v/v succinate-phosphate-glycine pH 6.0
Unit Cell:
a: 41.489 Å b: 64.975 Å c: 85.160 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.21 Solvent Content: 44.38
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.5500 32.35 3956 395 98.94 ? 0.3259 86.13
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.550 32.35 98.94 0.06635 ? 12.72 4.900 ? 3956 ? ? 60.27
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.550 2.641 97.14 ? ? 2.41 5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.953737 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.16_3549
XDS data reduction Mar 15, 2019 BUILT=20190315
Aimless data scaling 0.7.4
PHASER phasing 2.8.2