X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 A 2ul drop with 3 mg/ml S250A PCK, 5 mM Manganese chloride, 5mM Magnesium chloride, 2 mM ATP, 2mM Pyruvate, 1 mM EDTA, 200 mM Ammonium acetate, 100 mM Sodium acetate pH 4.8, 0.01 mM DTT, 12% PEG 4000 was added to 2 ul drop containing 0.01 mM Nickel chloride, 0.1 M Tris pH 8.5, 20% PEG 2000. After a week a rod like crystal was removed and soaked in a solution with 30% glycerol 1mM EDTA, 100 mM sodium acetate 200mM ammonium acetate and 12% PEG 4000 for 10 seconds and flash cooled in liquid notrogen
Unit Cell:
a: 124.910 Å b: 94.620 Å c: 46.350 Å α: 90.000° β: 96.210° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.32 Solvent Content: 46.87
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.7000 40.5000 58596 2930 99.5800 0.1691 0.2083 21.3601
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.7 40.5 99.59 0.1803 ? 9.63 3.8 ? 58603 ? ? 16.05
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.7 1.761 ? ? ? 1.25 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 105 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON CLSI BEAMLINE 08B1-1 0.8856 CLSI 08B1-1
Software
Software Name Purpose Version
PHENIX refinement 1.17.1_3660
XDS data reduction .
XDS data scaling .
MOLREP phasing .