X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 277 0.2 M sodium nitrate, 33% PEG3350
Unit Cell:
a: 37.273 Å b: 50.398 Å c: 114.497 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 2 21 21
Crystal Properties:
Matthew's Coefficient: 1.87 Solvent Content: 34.39
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.5890 46.1270 29406 1408 98.3200 0.1545 0.1890 15.5128
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.58 46.13 98.3 0.087 ? 17.4 5.8 ? 29409 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.59 1.66 90.0 ? ? 2.2 3.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRL BEAMLINE BL12-2 0.97945 SSRL BL12-2
Software
Software Name Purpose Version
PHENIX refinement 1.14
PDB_EXTRACT data extraction 3.25
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .