X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.8 290 15-18% PEG 3350, 100 mM Bis-Tris pH 6.8, 100 mM magnesium formate
Unit Cell:
a: 55.291 Å b: 68.616 Å c: 91.646 Å α: 69.550° β: 78.970° γ: 66.100°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.08 Solvent Content: 40.78
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.2000 42.4260 56623 2916 96.8600 0.2209 0.2645 37.9256
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.200 48.820 96.900 0.193 ? 5.000 3.300 ? 56682 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.200 2.260 96.300 ? ? ? 3.100 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.16_3549
XDS data reduction .
Aimless data scaling 0.7.4
PHASER phasing 2.8.2
PDB_EXTRACT data extraction 3.25