Summary
Structure Feature
Experiment
Ligands & Environment
6TUP
pdb_00006tup
10.2210/pdb6tup/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
Pseudomonas virus Pf1
Specimen Preperation
Sample Aggregation State
FILAMENT
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
Samples for cryo-EM were prepared by pipetting 2.5 ul of the sample onto freshly glow-discharged Quantifoil grids (Cu/Rh R2/2, 200 mesh). Grids were blotted for 2.5 seconds with a blot force of -15, 0.5 second drain and 0 second wait times.
3D Reconstruction
Reconstruction Method
HELICAL
Number of Particles
185002
Reported Resolution (Å)
3.2
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
HELICAL
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
BACKBONE TRACE
Refinement Target
Correlation coefficient
Overall B Value
93.74
Fitting Procedure
?
Details
The helical filament symmetry is only applied to the Pf4 coat protein and not the DNA. The reason for this is that the DNA bases are not resolved clearly due to averaging along the ssDNA genome of the phage, meaning that refinement of the protein into the map is of a higher quality than the ssDNA, where a poly-adenine model has been built.
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å
2
)
43
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
-1000
Maximum Defocus (nm)
-3000
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
105000
Calibrated Magnification
105000
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
PARTICLE SELECTION
RELION
2.0
IMAGE ACQUISITION
EPU
?
CTF CORRECTION
RELION
2.0
MODEL FITTING
Coot
?
MODEL REFINEMENT
PHENIX
?
INITIAL EULER ASSIGNMENT
RELION
2.0
FINAL EULER ASSIGNMENT
RELION
2.0
CLASSIFICATION
RELION
3.0
RECONSTRUCTION
RELION
3.0
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
Wiener filter implemented in the RELION refinement algorithm