Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
6SC2
pdb_00006sc2
10.2210/pdb6sc2/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
Dynein-2 complex
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
?
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
57265
Reported Resolution (Å)
3.9
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Above values for the motor domain map (EMD-4917). For the tail domain map (EMD-4918), number of particles used was 68623, resolution was 4.5 A using the FSC 0.143 cut-off, even/odd maps refined totally independent (gold standard), C1 symmetry.
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
?
Refinement Protocol
BACKBONE TRACE
Refinement Target
?
Overall B Value
?
Fitting Procedure
?
Details
EMD entries 4917 and 4918 (motor and tail domain reconstructions of human dynein-2 complex) were docked into a subtomogram average of IFT complex B and inhibited dynein-1b in anterograde IFT trains from C. reinhardtii cilia (EMD-4303) using Chimera's 'Fit in Map' command. The two DHC2 bundles connecting the tail and motor domain were modelled using SWISS-MODEL and RaptorX Contact (deposition as UNK).
Data Acquisition
Detector Type
GATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å
2
)
49.6
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
1000
Maximum Defocus (nm)
3500
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
105000
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
IMAGE ACQUISITION
EPU
?
CTF CORRECTION
Gctf
?
CTF CORRECTION
RELION
2.1
INITIAL EULER ASSIGNMENT
RELION
2.1
FINAL EULER ASSIGNMENT
RELION
2.1
RECONSTRUCTION
RELION
2.1
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
?