X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 293 0.1 M Bis-tris propane, 0.2 M sodium acetate, 24 % (w/v) PEG 3350
Unit Cell:
a: 74.684 Å b: 98.677 Å c: 207.100 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.45 Solvent Content: 49.80
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.3000 57.230 65968 3257 95.7700 0.1862 0.2115 41.9496
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.300 57.230 96.200 0.065 ? 13.800 4.200 ? 66028 ? ? 38.970
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.300 2.350 95.800 ? ? ? 4.000 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID30B 0.976 ESRF ID30B
Software
Software Name Purpose Version
PHENIX refinement .
Aimless data scaling 0.5.32
PDB_EXTRACT data extraction 3.24
XDS data reduction .
PHASER phasing .