X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.0 291.15 30 mM NaBr, 220 mM Kcitrate, glycerol 6%, 15-16% w/v PEG400
Unit Cell:
a: 62.882 Å b: 75.477 Å c: 118.777 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: I 2 2 2
Crystal Properties:
Matthew's Coefficient: 2.27 Solvent Content: 45.81
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.0600 48.3120 17615 528 98.4600 0.2047 0.2293 49.6164
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.060 63.700 98.800 0.076 ? 12.300 4.600 ? 17664 ? ? 36.130
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.060 2.120 88.600 ? ? ? 3.400 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 0.93300 ESRF ID14-2
Software
Software Name Purpose Version
PHENIX refinement 1.13_2998
MOSFLM data reduction .
Aimless data scaling 0.7.1
PDB_EXTRACT data extraction 3.24
PHENIX phasing .