X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 291 Tris-HCl, Peg8000, calcium acetate
Unit Cell:
a: 124.818 Å b: 124.818 Å c: 127.087 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 31
Crystal Properties:
Matthew's Coefficient: 2.91 Solvent Content: 57.73
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.800 44.526 54132 2701 99.24 0.2112 0.2602 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.7 50 98.9 ? ? 10.19 10.4 625210 60260 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.7 2.86 ? ? ? ? 10.3 4413
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON BESSY BEAMLINE 14.1 1.8814 BESSY 14.1
Software
Software Name Purpose Version
PHENIX refinement (1.14_3260: ???)
XDS data reduction .
XDS data scaling .
PHASER phasing .