X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 0.5 M lithium chloride, 100 mM Tris(hydroxymethyl)aminomethane hydrochloride (Tris-HCl), 28 % (w/v) polyethylenglycol 6000, pH 8.5
Unit Cell:
a: 72.540 Å b: 78.619 Å c: 77.055 Å α: 90.000° β: 115.110° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.48 Solvent Content: 50.44
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.4000 49.1600 28923 1523 98.4700 0.2380 0.2683 55.6980
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.4 49.2 98.8 ? ? 7 3.6 ? 30437 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.4 2.49 95.6 ? ? 0.98 3.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-2 0.873 ESRF ID23-2
Software
Software Name Purpose Version
REFMAC refinement 5.8.0238
PDB_EXTRACT data extraction 3.22
XDS data reduction .
XDS data scaling .
PHASER phasing .