X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.4 289 0.2 M magnesium acetate, 100 mM Bis-Tris adjusted with acetic acid to pH 5.0-5.75, 20-32% w/v PEG3350
Unit Cell:
a: 44.449 Å b: 51.235 Å c: 78.955 Å α: 90.000° β: 92.160° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.09 Solvent Content: 41.27
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.6790 42.9700 40615 2000 99.7700 0.1466 0.1879 18.4522
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.6790 44.420 99.800 0.074 ? 14.300 6.900 ? 40638 ? ? 15.210
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.680 1.710 97.300 ? ? ? 6.900 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
XDS data reduction .
Aimless data scaling 0.7.1
PHASER phasing 2.8.2
PHENIX refinement .
PDB_EXTRACT data extraction 3.25