6P01

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 285 16-18% PEG 8K, 0.1 M Tris pH 7.5-8.0, 0.1-0.2 M MgCl2.
Unit Cell:
a: 56.340 Å b: 97.040 Å c: 100.850 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.37 Solvent Content: 48.03
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.89 49.185 45191 2207 99.90 0.1772 0.2061 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.89 49.19 99.9 0.123 ? 10.6 6.1 ? 45256 ? ? 13.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.89 1.93 99.9 ? ? 3.0 6.0 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 23-ID-D 1.0332 APS 23-ID-D
Software
Software Name Purpose Version
PHENIX refinement (1.13_2998: ???)
iMOSFLM data reduction .
Aimless data scaling .
MOLREP phasing .