X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 17% PEG 8000, 20% ethylene glycol, 0.2 M sodium formate, 0.2 M ammonium acetate, 0.2 M trisodium citrate, 0.2 M sodium potassium L-tartrate, 10 mM DTT and 0.1 M Tris pH 7.9
Unit Cell:
a: 94.240 Å b: 154.080 Å c: 120.995 Å α: 90.00° β: 94.55° γ: 90.00°
Symmetry:
Space Group: I 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.69 Solvent Content: 54.34
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD FREE R-VALUE 2.80 43.19 41899 1997 98.9 0.202 0.238 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.80 47.49 99.0 0.152 ? 6.8 3.1 ? 41934 ? ? 49.10
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.80 2.91 96.9 ? ? 1.3 3.1 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.979 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement (DEV_3357: ???)
MOSFLM data reduction .
Aimless data scaling .
PHENIX phasing .