X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.4 293 MPD, sodium chloride, sodium acetate
Unit Cell:
a: 63.290 Å b: 63.290 Å c: 236.291 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: H 3 2
Crystal Properties:
Matthew's Coefficient: 2.3 Solvent Content: 47
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.531 39.382 26883 1342 95.85 0.1794 0.1982 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.53 78.8 96.1 0.028 ? 26.9 3.8 ? 26889 ? ? 12.6
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.53 1.56 99.4 ? ? 12.4 3.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRL BEAMLINE BL9-2 1 SSRL BL9-2
Software
Software Name Purpose Version
PHENIX refinement 1.10.1_2155
iMOSFLM data reduction .
Aimless data scaling .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback