X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.4 277 16% PEG 3,350, 0.1 M Bis-Tris Propane, pH 7.4, 5% 1-Propanol
Unit Cell:
a: 43.714 Å b: 117.635 Å c: 47.775 Å α: 90.00° β: 114.54° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.44 Solvent Content: 49.49
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.80 20.88 37699 2066 98.56 0.16259 0.20778 22.898
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.8 50 98.9 ? ? 41.78 4.6 ? 39797 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.8 1.83 95.9 ? ? 7.69 4.2 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-BM 0.979 APS 19-BM
Software
Software Name Purpose Version
REFMAC refinement 5.8.0135
HKL-3000 data reduction .
HKL-3000 data scaling .
MOLREP phasing .
Feedback Form