X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 277 18-20% V/V PEG 3350, 0.2M AMMONIUM CITRATE (PH 7)
Unit Cell:
a: 207.004 Å b: 45.652 Å c: 85.875 Å α: 90.000° β: 111.560° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.21 Solvent Content: 44.25
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.8310 36.8600 65729 3202 99.1900 0.1877 0.2189 25.0576
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.780 50.000 100.000 0.110 ? 5.900 6.400 ? 71799 ? ? 18.860
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.780 1.810 100.000 ? ? ? 5.100 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL18U1 0.979 SSRF BL18U1
Software
Software Name Purpose Version
HKL-2000 data reduction .
HKL-2000 data scaling .
PHENIX refinement 1.12_2829
PDB_EXTRACT data extraction 3.25
PHASER phasing 2.6.1