X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293.15 0.1M Sodium cacodylate pH6.5, 0.32M Ammonium sulfate, 9% PEG 8000, 5mM DTT
Unit Cell:
a: 71.926 Å b: 71.926 Å c: 65.798 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 31 2 1
Crystal Properties:
Matthew's Coefficient: 2.67 Solvent Content: 53.85
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.5000 20.0000 5870 280 86.6900 0.1996 0.2439 45.7940
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.500 50.000 86.600 0.098 ? 8.900 4.700 ? 6189 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.500 2.540 90.900 ? ? ? 4.400 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 HF 1.5418 ? ?
Software
Software Name Purpose Version
HKL-2000 data scaling .
MOLREP phasing 10.2.31
REFMAC refinement 5.5.0102
PDB_EXTRACT data extraction 3.25
Coot data reduction .