X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.5 295 0.1M Bis-Tris pH5.5, 15% PEG 3350, 20mM L-proline
Unit Cell:
a: 41.799 Å b: 60.296 Å c: 42.426 Å α: 90.000° β: 98.070° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.07 Solvent Content: 40.44
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.35 50 42348 2097 92.0100 0.1535 0.1885 24.4677
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.350 50.000 95.500 0.046 ? 11.100 6.300 ? 43712 ? ? 13.720
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.350 1.400 96.100 ? ? ? 6.300 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL17U1 0.97891 SSRF BL17U1
Software
Software Name Purpose Version
HKL-2000 data reduction .
SCALEPACK data scaling .
PHENIX refinement 1.13
PDB_EXTRACT data extraction 3.25
PHASER phasing .