X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.5 295 0.1M Bis-Tris pH5.5, 15% PEG 3350, 20mM L-proline
Unit Cell:
a: 40.795 Å b: 59.210 Å c: 42.041 Å α: 90.000° β: 93.410° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 1.98 Solvent Content: 37.80
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.1510 50.0 62106 3152 87.9400 0.1408 0.1604 22.7627
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.150 50.000 97.200 0.056 ? 9.300 5.300 ? 68710 ? ? 15.950
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.150 1.190 91.600 ? ? ? 4.300 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL17U1 0.97891 SSRF BL17U1
Software
Software Name Purpose Version
HKL-2000 data reduction .
SCALEPACK data scaling .
PHENIX refinement 1.13
PDB_EXTRACT data extraction 3.25
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback