X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 290 18% PEG 8000, 100mM sodium cacodylate, pH 6.5, 200mM calcium Acetate
Unit Cell:
a: 40.469 Å b: 60.811 Å c: 64.255 Å α: 101.182° β: 107.756° γ: 93.585°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.92 Solvent Content: 57.81
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.80 30.35 50623 2518 96.75 0.1651 0.2012 23.15
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.8 47.68 97.3 ? 0.089 17.42 2.5 ? 50805 ? ? 17.11
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.80 1.83 95.4 ? 0.335 2.36 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-G 0.97856 APS 21-ID-G
Software
Software Name Purpose Version
PHENIX refinement 1.14_3260
PHENIX refinement 1.14_3260
HKL-2000 data scaling .
PDB_EXTRACT data extraction 3.25
DENZO data reduction .
MOLREP phasing .