X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 295 50mM HEPES, pH 7.0, 4% PEG 8000, 100mM NaCl
Unit Cell:
a: 56.460 Å b: 88.030 Å c: 130.470 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 2 21 2
Crystal Properties:
Matthew's Coefficient: 2.80 Solvent Content: 56.11
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.832 72.973 57704 2925 99.46 0.2052 0.2424 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.83 88.03 99.7 0.095 ? 7.9 4.7 ? 57772 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.83 1.87 99.9 ? ? 1.3 4.9 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.972420 ESRF ID29
Software
Software Name Purpose Version
PHENIX refinement (1.14_3260: ???)
PDB_EXTRACT data extraction 3.24
MOSFLM data reduction .
Aimless data scaling .
PHASER phasing .