ELECTRON MICROSCOPY


Sample

Viruses

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument FEI VITROBOT MARK IV
Cryogen Name ETHANE
Sample Vitrification Details ?
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 41941
Reported Resolution (Å) 3.3
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol BACKBONE TRACE
Refinement Target ?
Overall B Value 174.7
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type GATAN ULTRASCAN 4000 (4k x 4k)
Electron Dose (electrons/Å2) 20
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model FEI TITAN KRIOS
Minimum Defocus (nm) ?
Maximum Defocus (nm) ?
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification 96000
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details ?
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION EMAN2 2.1
MODEL FITTING Coot 0.7.2.1
INITIAL EULER ASSIGNMENT jspr 2014-02-10
FINAL EULER ASSIGNMENT jspr 2014-02-10
CLASSIFICATION RELION 2.0
RECONSTRUCTION jspr 2014-02-10
MODEL REFINEMENT PHENIX ?
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
PHASE FLIPPING ONLY ?