X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.0 281.15 The reconstituted [Fe]-hydrogenase holoenzyme from M. aeolicus was crystallized in the anaerobic tent with gas phase 95%N2/5%H2 using 96-well 2-drop MRC Crystallization Plates (Molecular Dimensions, Suffolk, UK). For the initial screening, 0.7-ul of 24 mg/ml reconstituted [Fe]-hydrogenase was mixed with 0.7 ul of reservoir solution of crystallization kits under yellow light and incubated under the dark condition. The best diffracting crystal was obtained in one month in the crystallization reservoir solution containing 20% w/v polyethylene glycol 3350, 100-mM tri-sodium citrate pH 4.0 and 200-mM tri-sodium citrate.
Unit Cell:
a: 136.985 Å b: 136.985 Å c: 117.317 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: I 41 2 2
Crystal Properties:
Matthew's Coefficient: 3.74 Solvent Content: 67.17
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.30 26.62 25043 1229 100.0 0.172 0.192 43.63
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.30 48.43 100 0.155 ? 17.9 13.7 ? 25078 ? ? 39.33
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.30 2.42 100 ? ? 2.9 14.0 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE BM30A 0.97980 ESRF BM30A
Software
Software Name Purpose Version
BUSTER refinement 2.10.3
XDS data reduction .
SCALA data scaling 3.3.22
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback