Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
6H3C
pdb_00006h3c
10.2210/pdb6h3c/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
BRISC complex bound to SHMT2 alpha
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
LEICA EM GP
Cryogen Name
ETHANE
Sample Vitrification Details
A 4 ul sample was applied to the grid and a protocol consisting of 30 s pre-blot incubation, 2 s blotting and no post-blot incubation was utilized for vitrification.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
35595
Reported Resolution (Å)
3.9
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
Correlation coefficient and
Overall B Value
117
Fitting Procedure
?
Details
Initial fitting with done using COOT, Rosetta was used for amino acid sequence threading and flexible fitting. COOT and ISOLDE were used for local rebuilding. Phenix was used for atom displacement parameter (ADP / B-factor) refinement.
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å
2
)
45
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
?
Maximum Defocus (nm)
?
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
0
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
130000
Calibrated Magnification
58140
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
PARTICLE SELECTION
Gautomatch
0.53
IMAGE ACQUISITION
EPU
1.1.0.30
CTF CORRECTION
RELION
2.1
MODEL FITTING
Coot
0.8.9
MODEL FITTING
Rosetta
2018.09.60072
INITIAL EULER ASSIGNMENT
RELION
2.1
FINAL EULER ASSIGNMENT
RELION
2.1
CLASSIFICATION
RELION
2.1
RECONSTRUCTION
RELION
2.1
MODEL REFINEMENT
Rosetta
2018.09.60072
MODEL REFINEMENT
PHENIX
1.15-3459
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
CTF was determined using GCTF. CTF was corrected within RELION.