6G1T

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 293 precipitant solution: 0.2 M Ammonium citrate tribasic, pH 7.0, 20 % (w/v) PEG 3,350 protein buffer: 25 mM HEPES pH 7.6, 75 mM Na2SO4
Unit Cell:
a: 122.770 Å b: 44.170 Å c: 56.460 Å α: 90.000° β: 90.860° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.17 Solvent Content: 43.26
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.93 41.87 22900 ? 99.6 ? 0.2125 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.93 41.87 96.7 0.08 ? 12.9 5.6 ? 22900 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.93 2.0 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.9763 ESRF ID29
Software
Software Name Purpose Version
PHENIX refinement .
XDS data reduction .
Aimless data scaling .
PHASER phasing .